Removal
With one hand, using pliers, grasp the Mounted CryoLoop. Using your the other hand, hold the CrystalCap between your thumb and finger(s). With gentle authority twist the Mounted CryoLoop and Cap in opposing directions and pull the Mounted CryoLoop from the CrystalCap.
Replacement
Select a Mounted CryoLoop with the desired CryoLoop size. Notice the notches on the Mounted CryoLoop. A standard length Mounted CryoLoop is created by snapping the MicroTube at the second notch from the bottom. Remove the end using your fingers or diagonal cutter. Apply a drop of Super Glue to the top opening of the CrystalCap. Insert the Mounted CryoLoop into this opening and push until the Mounted CryoLoop is stopped by the bottom of the CrystalCap. Epoxy may be used instead of Super Glue for a more permanent fixation of the Mounted CryoLoop to the CrystalCap.
|
|
|
|
|
|